Sensitivity of remotely sensed pigment concentration via Mixture Density Networks (MDNs) to uncertainties from atmospheric correction

Zolfaghari, K, Pahlevan, N, Simis, SGH, O'Shea, RE and Duguay, CR 2022 Sensitivity of remotely sensed pigment concentration via Mixture Density Networks (MDNs) to uncertainties from atmospheric correction. Journal of Great Lakes Research. https://doi.org/10.1016/j.jglr.2022.12.010

[img]
Preview
Text
1-s2.0-S0380133022002696-main (1).pdf - Published Version
Available under License Creative Commons Attribution.

Download (4MB) | Preview
Official URL: http://dx.doi.org/10.1016/j.jglr.2022.12.010

Abstract/Summary

Lake Erie, the shallowest of the five North American Laurentian Great Lakes, exhibits degraded water quality associated with recurrent phytoplankton blooms. Optical remote sensing of these optically com�plex inland waters is challenging due to the uncertainties stemming from atmospheric correction (AC) procedures. In this study, the accuracy of remote sensing reflectance (Rrs) derived from three different AC algorithms applied to Ocean and Land Colour Instrument (OLCI) observations of western Lake Erie (WLE) is evaluated through comparison to a regional radiometric dataset. The effects of uncertainties in Rrs products on the retrieval of near-surface concentration of pigments, including chlorophyll-a (Chla) and phycocyanin (PC), from Mixture Density Networks (MDNs) are subsequently investigated. Results show that iCOR contained the fewest number of processed (unflagged) days per pixel, compared to ACOLITE and POLYMER, for parts of the lake. Limiting results to the matchup dataset in common between the three AC algorithms shows that iCOR and ACOLITE performed closely at 665 nm, while out�performing POLYMER, with the Median Symmetric Accuracy (MdSA) of �30 %, 28 %, and 53 %, respec�tively. MDN applied to iCOR- and ACOLITE-corrected data (MdSA < 37 %) outperformed MDN applied to POLYMER-corrected data in estimating Chla. Large uncertainties in satellite-derived Rrs propagated to uncertainties �100 % in PC estimates, although the model was able to recover concentrations along the 1:1 line. Despite the need for improvements in its cloud-masking scheme, we conclude that iCOR combined with MDNs produces adequate OLCI pigment products for studying and monitoring Chla across WLE

Item Type: Publication - Article
Additional Keywords: Sentinel-3, OLCI, POLYMER, iCOR, ACOLITE, MDNs
Divisions: Plymouth Marine Laboratory > Science Areas > Earth Observation Science and Applications
Depositing User: S Hawkins
Date made live: 25 Jan 2023 08:57
Last Modified: 25 Jan 2023 08:57
URI: https://plymsea.ac.uk/id/eprint/9845

Actions (login required)

View Item View Item