GO-SHIP Repeat Hydrography Nutrient Manual: The Precise and Accurate Determination of Dissolved Inorganic Nutrients in Seawater, Using Continuous Flow Analysis Methods

Becker, S, Aoyama, M, Woodward, EMS, Bakker, K, Coverly, SC, Mahaffey, C and Tanhua, T 2020 GO-SHIP Repeat Hydrography Nutrient Manual: The Precise and Accurate Determination of Dissolved Inorganic Nutrients in Seawater, Using Continuous Flow Analysis Methods. Frontiers in Marine Science, 7, 581790. 1-15. https://doi.org/10.3389/fmars.2020.581790

[img]
Preview
Text
GO-SHIP Nutrient Manual Published pdf.pdf - Published Version
Available under License Creative Commons Attribution.

Download (861kB) | Preview
Official URL: http://dx.doi.org/10.3389/fmars.2020.581790

Abstract/Summary

The GO-SHIP nutrient manual covers all aspects of nutrient analysis from basic sample collection and storage, specifically for Continuous Flow analysis using an Auto-Analyzer, and describes some specific nutrient methods for Nitrate, Nitrite, Silicate, Phosphate and Ammonium that are in use by many laboratories carrying out at-sea analysis and repeat hydrography sections across the world. The focus is on segmented flow analyzers not flow injection analyzers. It also covers laboratory best practices including quality control and quality assurance (QC/QA) procedures to obtain the best results, and suggests protocols for the use of reference materials (RM) and certified reference materials (CRMs).

Item Type: Publication - Article
Additional Information. Not used in RCUK Gateway to Research.: Correspondence: Susan Becker sbecker@ucsd.edu
Additional Keywords: The GO-SHIP nutrient manual covers all aspects of nutrient analysis from basic sample collection and storage, specifically for Continuous Flow analysis using an Auto-Analyzer, and describes some specific nutrient methods for Nitrate, Nitrite, Silicate, Phosphate and Ammonium that are in use by many laboratories carrying out at-sea analysis and repeat hydrography sections across the world. The focus is on segmented flow analyzers not flow injection analyzers. It also covers laboratory best practices including quality control and quality assurance (QC/QA) procedures to obtain the best results, and suggests protocols for the use of reference materials (RM) and certified reference materials (CRMs).
Divisions: Plymouth Marine Laboratory > National Capability categories > Single Centre NC - CLASS (expired)
Plymouth Marine Laboratory > National Capability categories > Western Channel Observatory
Plymouth Marine Laboratory > Science Areas > Marine Biochemistry and Observations
Depositing User: S Hawkins
Date made live: 03 Nov 2020 09:58
Last Modified: 03 Nov 2020 09:58
URI: https://plymsea.ac.uk/id/eprint/9069

Actions (login required)

View Item View Item